Alzan package errors (Alzan water heater error) If you have chosen the Alzan brand for your heating system, stay with us until the end of the article, here we have a complete list of Alzan package error codes along with their solutions for you dear ones. We have prepared it so that if a problem occurs in your Alzan package, you can refer to this article to troubleshoot and repair your Alzan package.
https://medium.com/@arezooahmadi7470/alzan-package-errors-66bca6c1bd46
Alzan package repair:
Creating an error and displaying error codes in the Alzan package means that there is a problem in your heating system. If you are unable to diagnose and repair your package by reading this article, leave the repair of your Alzan package to the experts of Tehran online service.
Our company with a brilliant history in the field of Alzan package repairs is ready to serve you all over the capital.
Alzan package error code:
Alzan company is one of the reliable brands, which has performed well in the field of heating systems production. To help in troubleshooting its packages, this company has implemented an intelligent troubleshooting system in its packages.
Error codes are displayed in different ways on different devices. In old devices, this was done by turning on the backlight or beeping. But in new generation heating systems that are often equipped with displays, error codes appear in English letters on the screen. One of the advantages of these codes over other methods is the possibility of transmitting more information about the error related to the type of problem or scope. its occurrence.
Alzan SGM24SF package error code:
Error code ER01 Alzan package:
Error description: limit sensor or limit switch error (the limit sensor is defective — the water temperature has risen — the wire or the wire head is damaged).
Error code ER02 Alzan package:
Error description: NTC sensor failure.
Error code ER03 Alzan package:
Error description: NTC sensor failure.
Error code ER04 Alzan package:
Description of the error: No flame formation (check the igniter) — if the flame is on and gives an error, reverse the plug and check the earth wire).
Error code ER05 Alzan package:
Description of the error: The fault is due to the fan pressure and the wet wiring (there is a possibility of the chimney being blocked).
Error code ER06 Alzan package:
Error description: The possibility of failure of the gas valve modulator is faulty — the method of testing the ohms of the bases should be between 70 and 90.
Error code ER07 Alzan package:
Error description: This error is related to the board — if this error is displayed several times, fix the board — if it appears again, the board is defective.
Error code ER08 Alzan package:
Error description: If it is displayed in hot water mode — the water temperature has gone above 92 degrees — (there is a possibility of clogging in the secondary converter), this error may occur due to the long flame.
Error code ER09 Alzan package:
Description of the error: The problem is with the fan or its wires. The fan fan pins are installed incorrectly — either the fan pin pins are broken or the fan pin is shorted.
Error code ER10 Alzan package:
Description of the error: low pressure of the heating system — (less than 0.5 bar, 9 devices must drain water and reach 1 bar — water pressure blockage due to sediment — need to adjust the water pressure adjustment screw.
Error code ER11 Alzan package:
Error description: The temperature of the heating system is below zero degrees — if the water temperature is zero or below zero, the anti-freeze system is active until the temperature rises, and the error appears.
Error code ER12 Alzan package:
Error description: The power voltage has reached 175 volts.
Error code ER13 Alzan package:
Error description: Check the ionizing rod — it is possible to connect to the body.
Error code ER14 Alzan package:
Error description: The gas valve is closed, but the ionizing rod detects the gas (there is a possibility of gas leakage, regardless of the lack of proper sealing of the connections).
Alzan SGM24SF2 package error code:
Error code E01 Alzan package:
Description of the error: fault in the formation of the flame — (lack of gas — defective electrode — defective gas valve — reversed zero phase).
Error code E02 Alzan package:
Description of the error: Fault in the limit sensor — the limit sensor has worked (replacing the sensor in case of failure and solving the temperature rise problem).
Error code E03 Alzan package:
Description of the error: fan compressor problem (fan compressor does not work — the fan compressor wire or plug is disconnected) check the smoke exit path — fan and compressor — correct the wiring or plugs.
Error code E04 Alzan package:
Description of error: water pressure (water pressure of the heating system is low — the water pressure is deposited — check the path (open the filling valve) check and clean the water pressure.
Error code E05 Alzan package:
Error description: heating sensor — heating NTC is broken — replace the sensor.
Error code E06 Alzan package:
Description of the error: Spa sensor — NTC of the consumption spa is broken — replace the sensor.
Error code E22 Alzan package:
Error description: Device memory error — Turn the device off and on until the memory is full.
Error code E40 Alzan package:
Error description: The input power has fluctuated — check the power protection and the input voltage.
Error code E72 Alzan package:
Error description: The combustion chamber has a problem.
Error code E76 Alzan package:
Description of error: The bobbin of the magelator is defective, replace it.
Error code E77 Alzan package:
Error description: The input voltage is defective.
Error code E78 Alzan package:
Error description: Heating NTC error — check correct operation.
Alzan package error code model SGM24SFN
Error code E01 Alzan package:
Error description: problems in flame formation and ignition system need manual reset.
Error code E02 Alzan package:
Error description: The limit thermostat has been activated due to an excessive increase in water temperature.
Error code E03 Alzan package:
Error description: The smoke thermostat has been activated due to a fault in the fan or combustion gas discharge path — manual reset is required.
Error code E04 Alzan package:
Error description: system water pressure drop — increase the pressure by filling valve.
Error code E05 Alzan package:
Error description: Error in the temperature sensor of the heating system.
Error code E06 Alzan package:
Error description: Error in the temperature sensor of the health spa.
Error code E07 Alzan package:
Error description: Chimney cleaner — Chimney needs cleaning — Check the chimney path.
Error code E08 Alzan package:
Error description: The antifreeze system is activated.
Error code E17 Alzan package:
Description of the error: problems in the gas solenoid valve or the gas and ignition circuit.
Error code E22 Alzan package:
Error description: Errors in the electronic system require a manual reset.
Alzan package error code, board model, fan seal:
Error code E05 Alzan package:
Description of the error: The problem is due to the fan pressure — the fan and wet wiring (there is a possibility that the chimney is clogged), in general, the error is due to the switch conduct being disconnected.
Error code E06 Alzan package:
Error description: The gas valve modulator is likely to be faulty — test method The ohms of the bases should be between 70 and 90.
Error code E07 Alzan package:
Error description: This error is related to the board — if this error is displayed several times, reset the board — if it appears again, the board is defective.
Error code E08 Alzan package:
Error description: If it is displayed in hot water mode — the water temperature has gone above 92 degrees — (there is a possibility of clogging in the secondary converter), this error may occur due to the long flame.
Error code E09 Alzan package:
Description of the error: The problem is with the fan compressor or its wires (the fan compressor bases are installed incorrectly — or the fan compressor bases are unifying, or in general, the hemat is short-circuited.
Error code E10 Alzan package:
Description of the error: low pressure of the heating system — (less than 0.5 bar) the device must drain and reach 1 bar — water pressure blockage due to sediment — need to adjust the water pressure adjustment screw.
Error code E11 Alzan package:
Description of the error: The temperature of the heating system is from zero degrees — if the water temperature is zero or below zero, the anti-freeze system is activated until the temperature rises, and the error appears.
Error code E12 Alzan package:
Error description: The input voltage has reached 175 volts.
Error code E13 Alzan package:
Error description: Check the ionizing rod — it is possible to connect to the body.
Error code E14 Alzan package:
Error description: The gas valve is closed, but the ionizing rod detects the gas (there is a possibility of gas leakage, regardless of the lack of proper sealing of the connections).
Error code ER01 Alzan package:
Error description: limit sensor or limit switch error (the limit sensor is faulty — the water temperature has risen — the wire or the wire is broken).
Error code ER02 Alzan package:
Error description: NTC sensor failure.
Error code ER03 Alzan package:
Error description: NTC sensor failure.
Error code ER04 Alzan package:
Description of the error: No flame formation (check the igniter) — if the flame is on and gives an error, reverse the plug and check the earth wire).
Error code: The package does not work in spa mode
Error description: If the sign of valve opening is visible, check the hot water consumption sensor — otherwise, make sure the connection of the flowmeter wire is correct — on the package board (seal board only), if the package is changed, make sure there is a jumper Please select option 01 from the F5 menu.
Alzan Mitos model package error code (Nordgas 6 buttons)
Error code E01 Alzan package:
Description of the error: fault in the formation of the flame — (lack of gas — defective electrode — defective gas valve — reversed zero phase).
Error code E02 Alzan package:
Description of the error: Fault in the limit sensor — the limit sensor has worked (replacing the sensor in case of failure and solving the temperature rise problem).
Error code E03 Alzan package:
Description of the error: fan pressure problem (the fan pressure does not work — the wire or plug of the fan pressure is disconnected) check the smoke exit path — fan and pressure — correct the wiring or plugs.
Error code E04 Alzan package:
Error description: water pressure (heating system water pressure is low — water pressure is deposited — check the path (open the filling valve), check and clean the water pressure).
Error code E05 Alzan package:
Error description: heating sensor — heating NTC is broken — replace the sensor.
Error code E06 Alzan package:
Description of the error: Spa sensor — NTC of the consumption spa is broken — replace the sensor.
Error code E22 Alzan package:
Error description: Device memory error — Turn the device off and on until the memory is full.
Error code E40 Alzan package:
Error description: The input power has fluctuated — check the power protection and the input voltage.
Error code E72 Alzan package:
Error description: The combustion chamber has a problem.
Error code E76 Alzan package:
Description of error: The bobbin of the magelator is defective, replace it.
Error code E77 Alzan package:
Error description: The input voltage is defective.
Error code E78 Alzan package:
Error description: Heating NTC error — check correct operation.
Fixing Alzan package errors at home:
If an error occurs in your Alzan package, first reset the package or unplug it. Wait for 5 to 10 minutes. Reconnect the package to the electricity, if you see an error, you should contact the Alzan package expert.
To prevent errors in the Alzan package:
In order to prevent errors in your Alzan package, it is enough to service your package every 6 months. The service of the package must be done by an experienced service technician every 6 months. Most of the problems caused in wall packages are due to the accumulation of debris inside the package. , which can be solved by acid washing and descaling of the package.
The cost of fixing the Alzan package error:
The cost of fixing the Alzan package error is determined according to the type of error created in it, and it is not possible to consider a fixed cost to fix all these errors. You can contact the experts of Tehran online service to know the approximate price of your repairs. Another thought is that these errors only indicate the cause of the error and it should be checked by package experts to fix the error caused by the device.